Ultra-Thin Power Supply

  • CM12V360W 360W Switching Power Supply
  • CM12V360W 360W Switching Power Supply
  • CM12V360W 360W Switching Power Supply
  • CM12V360W 360W Switching Power Supply
  • CM12V360W 360W Switching Power Supply
CM12V360W 360W Switching Power SupplyCM12V360W 360W Switching Power SupplyCM12V360W 360W Switching Power SupplyCM12V360W 360W Switching Power SupplyCM12V360W 360W Switching Power Supply

CM12V360W 360W Switching Power Supply

  • 360W Switching Power Supply
  • DC12V 30A
  • 100% full load burn-in test
  • Product description: ◆ Built in EMI filter with tiny ripple ◆ 100% full load burn-in test ◆ Protection: Short circuit/ Overload/ Over voltage/ Over temperature
  • INQUIRY   EMAIL

Features:

1. 360W Output Switching Power Supply
2. Output voltage & current: DC12V  30A
3. Input voltage range: 180~260VAC
4. Built in EMI filter with tiny ripple
5. 100% full load burn-in test
6. Forced air Cooling by built-in DC fan
7. Protection: Short circuit/ Overload/ Over voltage/ Over temperature
8. Built-in constant current limiting circuit (C.C.+C.V.mode);


Specification:

Model CM12V360W
Output DC output Voltage 12V±10%
Output Current Range 0-30A
Wave and Noise 120mVp-p
DC output Power 360W
Efficiency 85%
DC Voltage Adjustable Scope at full load)≦0.5%
Input Voltage Range 180~260VAC      47-63Hz
Input Current 1.6A/230V
Leakage Current <1mA/ 240VAC
Inrush Current Cold start 36A/ 230VAC
Protection Over-load 105%~135%,  Protection type: Constant current limiting,
recovers automatically after fault condition is removed
Over-voltage 105%---150% Rated Voltage, Protection type: Shut off
High-temperature RTH3>=65°C FAN ON<=55°C FAN OFF>=80°C Cut off output(5~15V)
Environment Working temperature and humidity -10°C~+50°C,   20~90%RH
Store temperature and humidity -20°C~+85°C,   10~95%RH
Temperature coefficient ±0.03%°C(0~50°C)
Vibration 10~500Hz,2G 10min./1cycle,Period for 60min,EACH AXES
Safety Withstand voltage I/P-O/P: 1.5KVAC, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC
Isolation resistance I/P-O/P,I/P-FG,O/P-FG: 100M Ohms/500VDC
Standard CE EMC Standard EN55015:2013+A1:2015, EN61547:2009, EN61000-3-2:2014, EN61000-3-33:2013
CE LVD Standard EN61347-2-13:2014+A1:2017, EB61347-1:2015
ROHS Standard IEC 62321: 2013, EPA3050B:1996, EN1122:2001, EPA3052:1996, EPA3060A, etc.
Other Dimension 215*115*30mm (L*W*H)
Weight 0.68kg
Notes 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. I/P-O/P: Input and output interval,  I/P-FG: Input and enclosure,  O/P-FG: Output and enclosure

Inquiry:
Scan the qr codeClose
the qr code